Mycotoxins
MultiSep AflaZon
SH-MultiSep AflaZonMycotoxins Aflatoxins Zearalenone SPE columns
MultiSep® columns contain a mixture of adsorbent materials designed for clean-up of all relevant food and feed commodities. These cost efficient clean-up columns are part of official AOAC and CEN methods and allow high sample throughput.- Analyte: Aflatoxin B1, Aflatoxin B2, Aflatoxin G1, Aflatoxin G2, Zearalenone, Zearalenol, Zearalanol
- Technology/Application: SPE columns
- Format: Column
DonStar Immunoaffinity columns
SH-DonStar IACMycotoxins Deoxynivalenol Trichotecenes B Immunoaffinity columns
StarLineTM immunoaffinity columns are designed for simple and reliable clean-up of a broad range of commodities, including feed. StarLineTM immunoaffinity columns can be used for purification and concentration of mycotoxins prior to analyses with HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.- Analyte: Deoxynivalenol
- Technology/Application: Immunoaffinity columns
- Product/Environment: Product Testing
BiopureTM Zearalenone Solid Standards
SH-ZEN Solid StandardsMycotoxins Zearalenone Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO Guide 31 and Eurachem guidelines.- Analyte: Zearalenone
- Technology/Application: Calibrants
- Formula: C18H22O5
BiopureTM Zearalenone - 100 µg/mL in acetonitrile
SH-ZON in ACNMycotoxins Zearalenone Calibrants
BiopureTM calibrants are high quality mycotoxin reference materials characterized by independent methods and accompanied by a certificate of analysis created in accordance with ISO Guide 31 and Eurachem guidelines.- Analyte: Zearalenone
- Technology/Application: Calibrants
- Solvent: Acetonitrile
BiopureTM U-[13C7]-Patulin - 25 µg/mL in acetonitrile
SH-13C7 Patulin in ACNMycotoxins Patulin C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Patulin
- Technology/Application: C13
- Solvent: Acetonitrile
BiopureTM U-[13C24]-T-2 Toxin - 25 µg/mL in acetonitrile
SH-13C24 T-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C T-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
BiopureTM U-[13C22]-HT-2 Toxin - 25 µg/mL in acetonitrile
SH-13C22 HT-2 in ACNMycotoxins T-2/HT-2 Trichotecenes A C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C HT-2 Toxin
- Technology/Application: C13
- Solvent: Acetonitrile
BiopureTM U-[13C21]-Deoxynivalenol-3-Glucoside - 10 µg/mL in acetonitrile
SH-DON-3-Glucoside in ACNMycotoxins Deoxynivalenol Trichotecenes B Calibrants
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Deoxynivalenol-3-Glucoside
- Technology/Application: Calibrants
- Solvent: Acetonitrile
BiopureTM U-[13C20]-Ochratoxin A - 10 µg/mL in acetonitrile
SH-13C20 OTA in ACNMycotoxins Ochratoxins C13
13C isotope fully labelled mycotoxins are internal standards for mass spectrometry. All the carbon atoms in the molecules are replaced by the stable carbon isotype. With 13C fully labelled mycotoxin standards, recovery losses from sample preparation and matrix effects in the MS source can be eliminated.- Analyte: 13C Ochratoxin A
- Technology/Application: C13
- Solvent: Acetonitrile